Filter Results By:

Products

Applications

Manufacturers

Showing results: 2341 - 2355 of 2628 items found.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Data AcQuisition And Real-Time Analysis

    Daqarta - Interstellar Research

    DAQARTA turns your Windows sound card into a precision laboratory instrument, loaded with advanced features. Put your sound card to work!Daqarta now allows remote control by an external program, custom reports, and custom data logging. Sample rates up to 256 kHz are supported, as well as slow input sampling (down to one sample per day or slower) while maintaining full output sample rates for simultaneous high-frequency stimulus generation. Allows slow scroll rates for chart recorder display of DC signals like temperature and pressure, and provides circuits to allow ordinary sound cards to handle DC measurements.

  • Four outputs FTTB CATV optical receiver

    B9428 - Hangzhou Huatai Optic Tech. Co., Ltd.

    Huatai B9428 product series, 47~862MHz operate bandwidth, output level Vo=88dBμV ( Pin=-2dBm ), suitable for FTTP optical fiber access network, which is a low power consumption, high performance, and excellent cost performance RFTV broadcast network ONU(Optical network unit). This series of product adopts high sensitivity receiving tube and Huatai special low noise matching circuit Under 3.8% modulation, when transmitting in full channels and with receiving power of -10dBm, the CNR can still reach high index of 45dB. Therefore, if adopting B9428, it is only need very low optical power to reach 45dB CNR required by the user.

  • Heavy Copper PCB

    VictoryPCB

    Your product descrVictory is a professional Advanced Circuit Manufacturer, We provide 3OZ ~ 6OZ Heavy Copper PCB.Heavy Copper PCB are generally used for high power distribution, heat dissipation, planar transformers, and power convertors. We can make up to 6oz Heavy Copper PCB.iption goes here.Monthy Capability: 3500 Sq M/MonthLayer: 4 LayersMaterial: FR4 TG170Dimension: 350.56mm*580mmFinished board thickness: 2.3mmOuter layer Finished copper thickness: 6ozInner layer base copper thickness: 6ozMin Trace Width/Space: 14milMin hole size: 0.2mmMin hole wall copper: ≥25UMSoldermask Color: Gloss BlackSilkscreen Color: WhiteSurface finishing: HALApplication field: Communication Field

  • Linear Bench Power Supplies Local Control, Ultra Low Ripple/Noise

    Series MSK - Kepco, Inc.

    Kepco's MSK linear power supplies provide a selection of five models, offering 100 Watts of stable benchtop power. They use a high gain linear (series pass) stabilizer circuit for ultra low noise and low ripple output, good stability, and accurate resettability, and they are MIL-STD-461 compliant.MSK's "Preview" switch (d-c on-off) allows voltage and current to be pre-set with the digital meters displaying the set values. At "d-c off," no voltage is applied to the output terminals and no load current needs to be drawn to set the current limit. At "d-c on," the set voltage is applied to the output terminals, the appropriate mode indicator illuminates and the meters indicate actual voltage and current.

  • Serial Parallel Interface

    Model 2303 - ICS Electronics

    * 2303 Board provides 40 high-power TTL I/O lines that can sink 23 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Dual Serial headers support conections with baud rate switch inputs or to a Serial Flat Ribon Cable Assembly. * Optional Relay Driver board drives 24-40 relays. * 114732 Board has the DIN connector on circuit side for use with the X3DVR Relay Driver Board or for piggyback mounting.* All other specifications are the same as listed above for the 2303.

  • Tone & Probe Kits

    Triplett Test Equipment & Tools

    ProTone Wire Locator Kit features a powerful tone generator and a filtered, ultra-bright lighted probe. The CTX590 functions as a high quality wire locating tool that uses an inductive probe to sense a tone placed on the wires by its associated tone generator. The tone generator provides RJ11, RJ45 and insulated alligator clip connections. The Red/Green LED on the probe indicates continuity, voltage, and polarity. The probe also includes an ultra bright LED tip, fluorescent light noise filter and sensitivity control. The CTX590 can be used for tracking down short circuits, telephone central office connections, and other wire locating applications. Includes (2) 9V batteries and case.

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • Programmable Multi Output DC Power Supply

    LQ6324P - Aplab Limited

    - Multi Output Linear DC Power Supply- Digitally Controlled Output Settings- Store / Load 10 Sets of Output Settings in Internal Memory- USB Interface Provided- Programmable Arbitrary Variable Output by Feeding Coefficient of the Curve- User Friendly Front End- Low Cost General Purpose Laboratory Bench Unit- Fully Protected against Overload and Short Circuit- 5V/5A with Over Voltage Crowbar Protection for Digital ICs- Three Independent Outputs Electrically isolated from Each Other- Electrically Floating Outputs up to 500V DC w.r.t. Ground- Precise Regulation, Low Ripple and Noise for Both Constant Voltage & Current Operation

  • MOD MONITOR

    TYPE HFX-1 - National RF, Inc

    The Type HFX-1 Modulation Monitor is an ancillary piece of equipment, which is used with narrow bandwidth, or older oscilloscopes to allow viewing of RF signals and particularly modulated signals as high as 55MHz. The equipment contains an RF signal source and a broadband mixing circuit which converts the high frequency signal to an intermediate frequency within the oscilloscope’s range. The frequency control dial is simply adjusted until the RF signal is viewed on the scope. BNC connectors are mounted on the rear panel to allow interconnect to the scope and RF probe. This product was previously called "oscilloscope frequency extender" and may be used to view other high frequency signals on older or narrow band scopes.

  • RF Milliwatt Meters

    Type NDB-2 and NDB-3 - National RF, Inc

    National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.

  • Programmable DC Power Source

    ODP3032 - KILTER ELECTRONIC CO.,LTD

    3.9 inch high resolution ( 480 x 320 pixels) TFT large LCD display,can clear visual display state and a plurality of relevant parametersTwo separate controllable output 0V ~ 30V / 3A,A fixed output 5V / 3A, total output of high power 195WThree channel output and electrical isolation,greatly reduce circuit interference Low ripple and noise of pure power:(<300 uVrms / 2 mVpp)Output resolution :1mV/1mAInternal implementation independent, parallel, series , positive-negative four kinds of work modes and automatic trackingOvercurrent and overvoltage protection function,Can easily set up the overvoltage and overcurrent protection parameters,effectively protect the load

  • Crossing Control Bypass Switch

    XCBS-DL - Green Switch Innovations

    The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.

  • Crossing Control Bypass Switch

    XCBS - Green Switch Innovations

    The XCBS is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the crossing control circuits to the designated terminals on the XCBS. The rotating "knife switch" on the left side of the XCBS allows the crossing warning system to be controlled for manual test purposes. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. The non-removable bypass key adds an additional level of security for the Bypass function. Optional hookup can be made to the auxiallary terminals to include the activation of a strobe or event recorder input when the XCBS is placed in the "bypass" position.

  • PXI 32 x SPDT Reed Relay

    40-110-121 - Pickering Interfaces Ltd.

    Our 40-110 and 40-115 range of reed relay switching modules are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 96 pin male micro-D connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120/125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, for slaving up to larger switches or for operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board thus easing the construction of complicated wiring.

Get Help